Primedic HeartSave SavePads Set
Electrode pads for the Primedic Heartsave Defibrillators
Please be advised that after placing your order, we require the serial number of your AED as these pads are made to order.
Please Note: These pads are a 3 pin socket / connector (1st & 2nd Generation)
- Specially packaged to protect the electrode pads prior to use
- Clear instructional diagrams to help the first responder apply the pads
- Includes 2 pin cable, razor, gloves and breathing mask
- Designed to be pre-connected, saving time in an emergency situation
- Usable in English, Dutch and Spanish
- Can be used on adults and children when unit is switched to paediatric
The Primedic HeartSave SavePads PreConnect are an essential piece of equipment when you’re looking to save the life of someone when using a Primedic defibrillator.
They are pre-connected by design, meaning that they should be connected when you receive them and they will be rescue ready when you need them. This saves time connecting the pads during the crucial minutes following a cardiac arrest and ensures the pads are connected and ready to be used.
Further benefits of having the pads pre-connected include the defibrillator regularly checking the pads to ensure they are in good operational condition daily. If there are any issues, the defibrillator will alert you of the problem so they can be replaced
Whats Included?
- 1 set of SavePads preconnected
- 2 Pin Cable
- Razor
- Gloves
- Breathing Mask
How to use
Once removed from the protective foil packaging and attached to the patient following the instructional images on the reverse of the electrodes, the pads will begin to analyse the heart of the patient and gather information.
The defibrillator will then use the data to decide whether treatment is the best option for the patient and will only allow that to happen if one of two conditions is present, ventricular fibrillation (VF) or ventricular tachycardia (VT).
About the Manufacturer
German manufacturers Primedic have been developing their AED products since 1973 and their current range of units are built with exceptional ease of use, ensuring that users of all abilities can help save a life.
Primedic, who operate under the medical company Metrax, provide high quality and efficient healthcare products and defibshop are proud to be the exclusive UK distributor of the Primedic HeartSave PAD Semi Automatic defibrillator.
More Information
If you have any further questions or queries regarding the Primedic HeartSave SavePads PreConnect then our friendly defibshop team is always on hand to offer support.
A defibrillator enthusiasts, we have a wealth of knowledge and we will make sure you find the right equipment you’re looking for. Call us on 0845 071 0830.
Defib Brand | Primedic |
---|---|
FDA Approved | No |
Dangerous Goods | No |
More Information
For further information about this product, get in touch with a member of our team on 0161 776 7422.
What is the Primecic HeartSave SavePads Set?
The Primedic HeartSave SavePads Set are electrode pads for the Primedic HeartSave 1st and 2nd generation defibrillators. These pre-connected electrode pads are crucial for delivering a lifesaving electrical shock to the heart during Sudden Cardiac Arrest, helping restore normal heart rhythm quickly and effectively. A 2 pin cable, a razor, gloves and a breathing mask are included in the package, along with clear instructional diagrams to help the responder with pad application.
Can the Primedic HeartSave Pads Set be used on children?
Yes, the Primedic HeartSave Pads Set can be used on adults and paediatrics with correct pad placement and when the defibrillator is switched to the correct mode.
The Primedic HeartSave Pads are compatible with the Primedic HeartSave series, allowing the responder to easily switch between “Child Mode” and “Adult Mode” depending on the casualty. For casualties over 8 years old or weighing more than 25kg, the defibrillator should be set to “Adult Mode.” For those under 8 years old or weighing less than 25kg, “Child Mode” should be selected to ensure safe and effective defibrillation for paediatric use.
How do I set up the Primedic HeartSave SavePads for use?
To set up the Primedic HeartSave SavePads for use, first remove them from the protective foil packaging. The back of each pad includes clear illustrations with instructions on proper placement on the patient’s bare chest. Consider shaving the casualty's chest area if needed to ensure the adhesion of the pads. After the pads are applied, the device will automatically begin analysing the heart rhythm. The defibrillation will only deliver a shock if it detects ventricular fibrillation (VF) or ventricular tachycardia (VT). Follow the defibrillator prompts for further instructions until emergency services arrive.
Can I reuse the Primedic HeartSave SavePads?
No, Primedic HeartSave SavePads are for one-time use only and must be disposed of after use. Once the pads have been applied to the casualty's skin and used during defibrillation, they must be discarded to ensure defibrillator reliability. Electrode pads must be replaced after each use, as the adhesive gel and electrical conductivity can degrade once they have been applied, even if no shock is delivered. Automated External Defibrillator pads have a set expiration date due to the conductive gel, which can deteriorate over time. Replacing the pads after use and checking the expiry dates ensures the defibrillator remains ready for emergencies.