CU Medical Bluetooth, 3 Lead ECG Module, iPAD SP2
Key Features
- Bluetooth 3 Lead ECG Monitoring for use with the iPAD SP2 defibrillator.
Bluetooth 3 Lead ECG Monitoring for use with the iPAD SP2 defibrillator unit. The 3 Lead ECG Monitoring means patients can be continuously monitored, even in a difficult environment or situation. It also allows patients to be moved and monitored at the same time, providing real-time heart analysis.
Defib Brand | iPAD (CU Medical) |
---|---|
FDA Approved | No |
Dangerous Goods | No |
More Information
Designed for use with the iPAD SP2 defibrillator unit, this 3 Lead ECG Monitoring equipment allows users to monitor patients continuously regardless of the environment the rescue is taking place in.
For further information about this product, get in touch with a member of our team on 0161 776 7422.
What defibrillator is compatible with the Bluetooth 3-Lead ECG Module?
The Bluetooth 3-Lead ECG Module is compatible with the iPAD SP2 defibrillator unit. The iPAD SP2 defibrillator is designed for trained personnel, such as medical professionals, who require enhanced functionality.
The Bluetooth 3 Lead ECG Monitoring allows responders to continuously monitor casualties, providing additional clinical information than entry-level defibrillators.
What is the purpose of the Bluetooth 3-Lead ECG Module for the iPAD SP2?
The purpose of the Bluetooth 3-Lead ECG Module for the iPAD SP2 allows monitoring of a casualty's heart rhythm through a 3-lead ECG system, allowing responders to assess cardiac function accurately. The Bluetooth lead also allows patients to be continuously moved and monitored at the same time, providing real-time heart analysis.
With a Bluetooth connection, there’s a reduced risk of wire entanglement or detachment. The continuous monitoring allows responders to gain critical insights into cardiac function, helping to guide timely, informed decisions when responding to Sudden Cardiac Arrest.
What is the benefit of using a 3-lead ECG during Sudden Cardiac Arrest?
The benefit of using a 3-lead ECG during Sudden Cardiac Arrest allows for detailed recordings of the heart’s activity, helping responders make informed treatment decisions. Responders can find out the heart rate, and rhythm, as well as more detailed information about the heart, including if one P wave is present for each QRS and if the rhythm requires treatment. The main goal of using a 3-lead is to monitor changes in heart rate or rhythm, providing critical insights that guide effective resuscitation efforts and optimise outcomes during Sudden Cardiac Arrest.
Do I need to take any precautions when using the CU Medical iPAD SP2 Defibrillator Bluetooth 3-Lead?
When using the CU Medical iPAD SP2 defibrillator Bluetooth 3 Lead, responders should follow a few precautions:
- Keep the module away from water/ heat: Avoid exposing the CU Medical iPAD SP2 defibrillator 3-Lead ECG Module to moisture or high temperatures, which can affect performance.
- Follow the setup instructions: Safely secure the module and leads, and confirm that the Bluetooth connection is stable before use.
- Maintain a safe distance: Avoid using the module near other devices that could interfere with the Bluetooth signal, ensuring accurate monitoring.
- Regularly inspect for wear and tear: Before use, check the leads and module for any signs of damage to ensure it is functioning properly.